LCS Mobile Bearing Knee Arthroplasty

Lieferzeit: Lieferbar innerhalb 14 Tagen

106,99 

A 25 Years Worldwide Review

ISBN: 3642639445
ISBN 13: 9783642639449
Herausgeber: Karel J Hamelynck/James B Stiehl
Verlag: Springer Verlag GmbH
Umfang: XIX, 371 S., 208 s/w Illustr., 623 farbige Illustr., 371 p. 831 illus., 623 illus. in color.
Erscheinungsdatum: 23.08.2014
Auflage: 1/2014
Produktform: Kartoniert
Einband: KT

This book reviews the LCS Mobile Bearing Arthroplasty which has been enthusiastically embraced by surgeons worldwide since introduction in 1977. Dr. Frederick Buechel and Dr. Mike Pappas developed a total knee prosthesis based on the concepts of low contact stress with unconstrained articulation using a mobile polyethylene bearing and highly conforming geometry. The long-term clinical results and evolutionary changes in surgical technique and understanding of total knee arthroplasty will be discussed. Recent scientific methodologies including wear simulation and fluoroscopic kinematic analysis have provided enlightening insight to clinical performance. Future modifications to the implant system will be described. Surgeons interested in proposing future designs using the mobile bearing concept will benefit from the knowledge of this experience.

Artikelnummer: 7052881 Kategorie:

Beschreibung

Worldwide experience with the Lcs- mobile bearing total knee prosthesis has been unpar alleled both in terms of enduring popularity and outstanding long-term clinical results. Buechel and Pappas's design was based on the principles of; restoring anatomical joint function to as near normal as possible, minimising contact stresses to avoid wear and darn age to the bearing surfaces. and finally the idea that constraint should refiect the need for mobility, to avoid shear stresses and loosening of the implant. In 1977, the LCS knee was implanted by Dr. Frederick Buechel. This was the first mobile bearing, tri-compartmental knee implant. This was also the first to successfully address the key issues ofloosening, wear and patello-femoral problems associated with earlier designs. The unique design solution was the creation of a common articulating geometry for the tibia and patella on the distal femoral surface. This resulted in a tibial and patellar articulation that was mobile in nature, but with an identical radius of curvature and conformity. The mobile bearing concept was considered sufficiently novel and unproven that the US FDA (Food & Drug Administration) required that it be validated in an Investigational Device Evaluation (IDE). An FDA IDE study involving 25 US surgeons was initiated in 1981. Validation of the clinical success of the device in this study resulted in FDA approval of the LCS, Knee (for cemented, tri-compartmental use) in 1985.

Das könnte Ihnen auch gefallen …